| FAS8200 PER HA PAIR SPECIFICATIONS (ACTIVE-ACTIVE DUAL CONTROLLER) |
| Maximum drives (HDD/SSD) |
480/480 |
| Maximum capacity |
4.8PB |
| Controller form factor |
Single-enclosure HA; |
| 2 controllers in single 3U chassis |
| Memory |
256GB |
|
Maximum onboard NVMe Flash CacheTM
|
4TB |
| Maximum Flash Pool capacity |
48TB |
| Combined flash total |
48TB |
| NVRAM |
16GB |
| PCIe expansion slots |
4 |
| Onboard I/O: UTA2 |
8 |
| (8Gb/16Gb FC, GbE/10GbE, or FCVI ports [MetroCluster only]) |
| Onboard I/O: 10GbE |
4 |
| Onboard 10GbE Base-T |
4 |
| Onboard I/O: 12Gb SAS |
8 |
| Storage networking supported |
FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB |
| OS version |
ONTAP® 9.1 |
| RC1 or higher |
| High-availability features |
Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies. |
| Supported Configurations ONTAP 9.1 or higher |
Hardware cluster configurations: |
| Two-node switchless or switched cluster |
| Clusters of HA pairs |
| MetroCluster configurations for synchronous replication: |
| 2-node |
| 4-node: two x 2-node switched or switchless clusters with fabric-attached (switched) storage; 4 nodes total: a 2-node active-active cluster at each site) |
| 8-node (NAS-only): four x 2-node switched or switchless clusters with fabric-attached (switched) storage; 8 nodes total: a 4-node cluster at each site) |
| Disk shelves supported |
DS224C (2U, 24 drives, 2.5” SFF, 12Gb) |
| DS212C (2U, 12 drives, 3.5”LFF, 12Gb) |
| DS2246 (2U; 24 drives, 2.5" SFF, 6Gb) |
| DS4246 (4U; 24 drives, 3.5" LFF, 6Gb) |
| DS4246 (DS4243 with IOM3 changed to IOM6) |
| DS4486 (4U; 48 drives, 3.5" LFF, 6Gb) |
| See NetApp Disk Shelves and Storage Media for more details on each disk shelf and supported drive types. |
| Maximum RAID group sizes |
RAID-TEC™ (triple parity) |
| SSDs and Performance HDDs: 29 (26 data disks plus 3 parity disks) |
| Capacity HDDs: 21 (18 data disks plus 3 parity disks) |
| RAID 6 (RAID-DP®) |
| SSDs and Performance HDDs: 28 (26 data disks plus 2 parity disks) |
| Capacity HDDs: 20 (18 data disks plus 2 parity disks) |
| RAID 4 |
| SSDs and Performance HDDs: 14 (13 data disks plus 1 parity disk) |
| Capacity HDDs: 7 (6 data disks plus 1 parity disk) |
| RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®) |
| Operating systems supported |
Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows Server 2016, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX® |
| Max. number of LUNs |
12,288 |
| Number of supported SAN hosts |
8,192 |
| FlexVol® volumes |
Up to 1,000 per controller |
| Snapshot® copies |
Up to 255,000 per controller |
| Maximum volume size |
100TB |
| Maximum aggregate size |
400TB |