FAS8080 EX |
FAS8060 |
FAS8040 |
FAS8020 |
PER HA PAIR SPECIFICATIONS (ACTIVE-ACTIVE DUAL CONTROLLER) |
Maximum capacity |
14400TB |
12000TB |
7200TB |
4800TB |
Maximum Flash Pool capacity |
144TB |
72TB |
48TB |
24TB |
Maximum drives |
1,440 |
1,200 |
720 |
480 |
Controller form factor |
Dual enclosure HA; |
Dual-enclosure HA; 2 controllers and 2 IOXMs in two 6U chassis; total of 12U or |
Single-enclosure HA; 2 controllers in single 6U chassis |
Single-enclosure HA; |
2 controllers and 2 IOXMs in two 6U chassis; total of 12U |
Single-enclosure HA; 2 controllers in single 6U chassis |
2 controllers in single 3U chassis |
Memory |
256GB |
128GB |
64GB |
48GB |
Maximum Flash Cache™ |
24TB |
8TB |
4TB |
3TB |
Maximum Flash Pool |
144TB |
72TB |
48TB |
24TB |
Combined flash total |
144TB |
72TB |
48TB |
24TB |
NVRAM |
32GB |
16GB |
16GB |
8GB |
PCIe expansion slots |
24 |
8 or 24[1] |
8 |
4 |
Onboard I/O: UTA2 |
8 |
8 |
8 |
4 |
(10GbE/FCoE, 16Gb FC) |
Onboard I/O: 10GbE |
8 |
8 |
8 |
4 |
Onboard I/O: GbE |
8 |
8 |
8 |
4 |
Onboard I/O: 6Gb SAS |
8 |
8 |
8 |
4 |
Storage networking supported |
FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB |
OS version |
ONTAP® 8.2.2 RC1 or higher |
ONTAP 8.2.1 RC2 or higher |
High-availability features |
Alternate Control Path (ACP); Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optic |
Supported configurations |
Hardware cluster configurations: |
|
Single-node cluster |
|
Two-node switchless or switched cluster |
ONTAP 9, 8.3 |
Clusters of HA pairs |
|
MetroCluster configurations for synchronous replication: |
|
2-node |
|
4-node: two x 2-node switched or switchless clusters with fabric-attached (switched) storage; 4 nodes total: a 2-node active-active cluster at each site) |
|
8-node (NAS-only): four x 2-node switched or switchless clusters with fabric-attached (switched) storage; 8 nodes total: a 4-node cluster at each site) |
|
Consult the Interoperability Matrix Tool for FAS8000 support on earlier versions of ONTAP software. |
Disk shelves supported |
DS212C (2U; 12 drives, 3.5” LFF, 12Gb) |
DS224C (2U; 24 drives, 2.5" SFF, 12Gb) |
DS2246 (2U; 24 drives, 2.5" SFF, 6Gb) |
DS4246 (4U; 24 drives, 3.5" LFF, 6Gb) |
DS4486 (4U; 48 drives, 3.5" LFF, 6Gb) |
DS4243[2] (4U; 24 drives, 3.5" LFF) supported for upgrades only with ONTAP 9 |
DS4246 (DS4243 with IOM6 added) – supported in ONTAP 9.1+ |
DS14[2] disk shelves (mk2-AT, mk4) are supported for upgrades only, not supported in ONTAP 9+ |
See NetApp Disk Shelves and Storage Media for more details on each disk shelf and supported drive types. |
Maximum RAID group sizes |
RAID-TEC™ (triple parity, ONTAP 9) |
SSDs and Performance HDDs: 29 (26 data disks plus 3 parity disks) |
Capacity HDDs: 21 (18 data disks plus 3 parity disks) |
RAID 6 (RAID-DP®) |
SSDs and Performance HDDs: 28 (26 data disks plus 2 parity disks) |
Capacity HDDs: 20 (18 data disks plus 2 parity disks) |
RAID 4 |
SSDs and Performance HDDs: 14 (13 data disks plus 1 parity disk) |
Capacity HDDs: 7 (6 data disks plus 1 parity disk) |
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®) |
Operating systems supported |
Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows XP, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX® |
Max. number of LUNs |
FAS8020/FAS8040: 8,192 (ONTAP 9 and 8.3.x) |
FAS8060/FAS8080: 12,288 (ONTAP 9 and 8.3.x) |
7-mode, all FAS8000 systems: 2048 |
Number of supported SAN hosts |
FAS8020/FAS8040: 4,096 (ONTAP 9 and 8.3.x) |
FAS8060/FAS8080: 8,192 (ONTAP 9 and 8.3.x) |
7-mode, all FAS8000 systems: Up to 512 hosts per HA pair |
FlexVol® volumes |
(In hardware clusters) Up to 1,000 per controller; (7-mode) up to 500 per controller |
Snapshot® copies |
Up to 255,000 per controller |
Maximum volume size |
100TB |
100TB |
100TB |
70TB |
Maximum aggregate size |
400TB |
400TB |
324TB |
324TB |
Maximum Port Count (Includes Integrated Ports and PCIe Expansion Slots) |
FC target ports (16Gb autoranging) |
64 |
64 |
24 |
12 |
FC target ports (4Gb or 8Gb) |
64 |
64 |
40 |
20 |
FCoE target ports, UTA (max.) |
32 |
32 |
24 |
12 |
10GbE ports (max.) |
64 |
64 |
32 |
16 |
GbE ports (max.) |
72 |
72 |
40 |
20 |
6Gb/12Gb SAS ports (max.) |
56 |
56 |
40 |
20 |
FC initiator ports (max.) |
72 |
72 |
40 |
20 |
Maximum Adapters |
Dual 10GbE (optical or copper) |
16 |
16 |
8 |
4 |
Dual 10Gbase-T (RJ-45,CAT 6A-E) |
16 |
16 |
8 |
4 |
Quad GbE (copper) |
16 |
16 |
8 |
4 |
Dual 10GbE/FCoE 16Gb FC Unified Target Adapter 2 (UTA2, optical or copper for 10GbE/FCoE deployments, optical for 16Gb FC) |
24 |
24 |
8 |
4 |
8Gb FC target |
16 |
16 |
8 |
4 |
Flash Cache Performance Acceleration Module (2TB) |
12 |
4 |
2 |
0 |
Flash Cache Performance Acceleration Module (1TB) |
24 |
8 |
4 |
2 |
Flash Cache Performance Acceleration Module (512GB) |
24 |
16 |
8 |
4 |
Quad 6Gb SAS storage HBA |
12 |
8 |
8 |
4 |
Quad 12Gb SAS storage HBA |
12 |
8 |
8 |
4 |
Quad 4Gb FC storage/tape HBA (fiber) |
16 |
8 |
8 |
4 |